Audit of
following 2 WIs was done in TM Shop. Report is as follows:-
Hitachi Field Coils( W 23.024):-
Points noticed (In continuation of audit
done on this WI earlier):-
- Use of profile jigs ING-002 and ING-005 was not to be done on all
coils.
- GUAT-CN-3 insulation sheet ( of M/S Perfect, Kolkata; approved
make?) should not be provided AFTER layer baking as it was prescribed
BEFORE layer baking as per WI para 3.2.8.
VPI of Hitachi Field Coils( W 23.025):-
Points noticed:-
- Some of the varnish DER 332 (one of the three components of
HEW-290 of HEW 290) used after vacuuming was checked for expiry date.
- Tank for making HEW-290 was got cleaned of dirt due to prolonged use.
- Baking jigs INJ-006 (MP) and INJ-013 (CP) were being sent for calibration.
- Cycle time as prescribed in the WI for initial 12 hours preheating
of the job , then 3 hrs. pressure application, then 15 hrs rotary baking
then 5 +15 hrs baking was being compared with actual
in the interest of production.
This is excellent information. Thanks for sharing.
ReplyDeleteAccording to the principle of Trickle Impregnation, activated resin is trickled in a thin jet on to the rotating preheated winding. The resin immediately gets heated and its viscosity is reduced
Trickle Impregnation Technique
Varnishing Machines
Batch Type Trickle Impregnating Machine
Index Type Trickle Impregnating Machine
Vacuum / Pressure Impregnation Plants Manufacturer
Vacuum / Pressure Impregnation Plants supplier
Vacuum / Pressure Impregnation Plants exporter
Thanks for Shearing This Post
ReplyDeleteAR Engineering is a Manufacture and Supplier Of Transformer Oil Filtration Plant, Industrial Oil Purification System, Trickle Impregnating Machine and Vacuum Pressure Impregnation Plant.
Industrial Oil Purification System
Vacuum Pressure Impregnation Plant
Batch Type Trickle Impregnating Machine
Index Type Trickle Impregnating Machine
Trickle and Roll Dip Impregnation Machine
Single Stage Transformer Oil Filtration Plant
Two Stage Transformer Oil Filtration Plant